Influence of low temperature on bronchodilatation induced by terbutaline administered by metered dose or dry powder inhalers in asthmatics.
2000
Low temperatures may affect dose delivery efficacy and clinical effectiveness of medication aerosols. In this study we examine the effect of cold ambient temperature on the bronchodilatation produced by terbutaline delivered from a chlorofluorocarbon pressurized metered dose inhaler (pMDI) compared to a multi-dose dry powder inhaler (DPI). Fourteen stable asthmatics were studied on two consecutive days. On day 1, after measuring FEV1 at room temperature (22 degrees C), each patient was randomized to receive 500 microg of terbutaline delivered from pMDI or DPI stored for 24 h at 22 degrees C with FEV1 recorded 20 min post-dose; then, patients were placed in a chamber at -10 degrees C, and af…
Handling forces for the use of different inhaler devices.
2019
Abstract Age and comorbidities can impact on the success of handling an inhaler. In this pilot study, we assessed finger strength in 62 participants (aged 5–17 years [n = 20], 18–65 years [n = 22] and > 65 years [n = 20]) by using different types of inhalers with integrated sensors (Respimat®, Breezhaler®, Aerolizer®, Genuair®, Diskus®, Ellipta®, HandiHaler®, Turbohaler® and a pressurized metered-dose inhaler [Atrovent®]). Parameters under investigation included the spontaneous and maximum achievable force and torque required to operate devices. Satisfaction with individual inhalers, and the relationship between satisfaction and strength, were also assessed. There was a marked difference in…
Lung deposition of extrafine vs non-extrafine triple therapies in patients with COPD using Functional Respiratory Imaging (FRI)
2019
Introduction: FRI is a validated computational fluid dynamics (CFD)-based technique using aerosol delivery performance profile, patients’ high-resolution lung CT scans and patient-derived inhalation profiles to simulate aerosol lung deposition. Aims and Objectives: To evaluate lung deposition patterns of extrafine beclometasone dipropionate/formoterol fumarate/glycopyrronium [BDP/FF/G; TRIMBOW®] pressurized metered dose inhaler (pMDI) and non-extrafine fluticasone furoate/vilanterol/umeclidinium [FluF/VI/UMEC; TRELEGY® ELLIPTA®] dry powder inhaler (DPI) in patients with stable COPD and moderate to very severe airflow obstruction. Methods: Intrathoracic depositions of the inhaled corticoster…
Statistical tools and control of internal lubricant content of inhalation grade HPMC capsules during manufacture
2016
The internal lubricant content (ILC) of inhalation grade HPMC capsules is a key factor to ensure good powder release when the patient inhales a medicine from a dry powder inhaler (DPI). Powder release from capsules has been shown to be influenced by the ILC. The characteristics used to measure this are the emitted dose, fine particle fraction and mass median aerodynamic diameter. In addition the ILC level is critical for capsule shell manufacture because it is an essential part of the process that cannot work without it. An experiment has been applied to the manufacture of inhalation capsules with the required ILC. A full factorial model was used to identify the controlling factors and from…
Inhalation therapy in the next decade
2018
This article is distributed under the terms of the Creative Commons Attribution Noncommercial License (by-nc 4.0) which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.
A dose-ranging study of indacaterol in obstructive airways disease, with a tiotropium comparison.
2008
This dose-ranging study assessed the bronchodilator efficacy and tolerability of indacaterol, a novel once-daily inhaled beta2-agonist, in subjects clinically diagnosed with COPD. Comparative data with tiotropium were collected. In the double-blind, core period of the study, 635 subjects with COPD (prebronchodilator FEV(1)40% of predicted and > or =1.0L; FEV1/FVC <70%) were randomized to receive indacaterol 50, 100, 200 or 400microg or placebo via multi-dose dry powder inhaler, or indacaterol 400microg via single-dose dry powder inhaler, once daily for 7 days. After completing double-blind treatment and washout, a subset of subjects from each treatment group entered an open-label extension …
The inhalation manager: a new computer-based device to assess inhalation technique and drug delivery to the patient.
2003
The rational choice of an inhalation device is a cornerstone in the effective management of asthma and COPD. In this publication, we describe the development of a new system, the Inhalation Manager, which, for the first time, offers the possibility to assess the entire inhalation maneuver of patients using original devices under everyday conditions. So far the Inhalation Manager allows the measurement of inspiratory maneuvers of patients through placebo inhalation devices of the most common breath-actuated CFC-free inhalers in the market for the three main glucocorticosteroids Budesonide [Turbohaler (TH), dry powder inhaler (DPI)], Beclomethasone dipropionate [Autohaler (AH), breath-actuate…
Inhaler mishandling remains common in real life and is associated with reduced disease control
2011
SummaryProper inhaler technique is crucial for effective management of asthma and COPD. This multicentre, cross-sectional, observational study investigates the prevalence of inhaler mishandling in a large population of experienced patients referring to chest clinics; to analyze the variables associated with misuse and the relationship between inhaler handling and health-care resources use and disease control.We enrolled 1664 adult subjects (mean age 62 years) affected mostly by COPD (52%) and asthma (42%). Respectively, 843 and 1113 patients were using MDIs and DPIs at home; of the latter, the users of Aerolizer®, Diskus®, HandiHaler® and Turbuhaler® were 82, 467, 505 and 361.We have a tota…
[Perception of dyspnea and treatment adherence in asthmatic patients].
2008
OBJECTIVE: The majority of studies show that treatment adherence in chronic diseases such as asthma does not exceed 50%. Although the reasons may vary, it is clear that lack of treatment adherence is a determining factor in poor disease control. An association has also been observed between lack of perception of dyspnea and difficult-to-control asthma and with the occurrence of fatal or near-fatal asthma attacks. In this study we therefore attempted to demonstrate that one of the reasons that asthmatic patients do not adhere to treatment is a failure to perceive dyspnea associated with bronchial obstruction. PATIENTS AND METHODS: We analyzed 2 groups of patients with moderate persistent ast…
Effects of a structured educational intervention in moderate-to-severe elderly asthmatic subjects.
2019
Background: Adherence to inhaled drugs is linked to patients’ satisfaction with their device, and an incorrect use can negatively affect the outcomes of asthma treatment. We speculated that this is particularly true in elderly asthmatic subjects. Aim: We performed a national pre-post interventional multicentre study, enrolling moderate-to-severe asthmatic subjects aged ≥65 years treated with fixed inhaled combination drugs by dry powder inhaler (DPI) or pressurized metered dose inhaler (pMDI). Adherence and critical errors were evaluated by means of validated questionnaires at first visit (V1) and after 3–6 months (V2). At V1, subjects underwent intensive training on the correct use of the…